Titanmagnetics also for nasal septum prosthesis
/in Allgemein @en, News /by Sandra GallitzkiNasal septum prosthesis can close a fully perforated nasal septum defect.
New, plane Titanmagnetics available for obturators
/in Allgemein @en, News /by Sandra GallitzkiThe contact surfaces of the W-Line magnets are flat and can be used from both sides.
larger drill sleeves in double sleeve system
/in Allgemein @en, News /by Sascha MetznerTube in Tube drill sleeves – but bigger
A new double sleeve system is now available under the name CeHa-drill sleeves.
With an outer sleeve of 4.5 mm diameter (1 mm larger than universal system) it’s possible to guide more and larger drill diameters.
There are 14 different inner sleeve diameters from 1.6 to 3.8 mm available. The lengths is 5.0mm. The sleeves are made of surgical grade titanium and have a funnel shaped entry for easiey drill access.
how does the double sleeve principle work?
The outer sleeve is fixed in the surgical template (pressing or gluing). With the exchangeble inner sleeves the surgical template can be adapted to the different drill diameters.
Of course the inner sleeves can be used directly in the surgical guide without an outer sleeve.
The sleeve geometries are part of the Steco libraries of common implant planning software (or will be published soon). With this the CeHa drill sleeves can be used for digital surgical guide process.
Why another system?
The CeHa double sleeve system is not really new. We have been manufacturing the sleeves for many years and now take over the distributership from our partner C-Hafner. The sleeves used to be part of the CeHa Implant system (med3D).
How to order?
Get a complete list of the CeHa drill sleves and accessories here and order via email, phone or our distributors.
Open drill sleeve in 3Shape
/0 Comments/in Allgemein @en, News /by Sascha Metzneropen drill sleeve
The StecoGuide outer sleeve is now available in the laterally open version in 3Shape Implant Studio. The open outer sleeve is part of the universal StecoGuide double sleeve system (tube in tube). It allows an easier axess for the inner sleeve and the surgical drill in narrow space situations.
New drill sleeve library in 3Shape
The open outer sleeve is available in a separate library. To use the sleeve the library (open outer sleeve) has to be selected. It is shown beside the normal Steco library which contains all other StecoGuide drill sleeves. The new library contains only the open outer sleeve. It can be positioned in any height above the implant and can be rotated together with the implant to adjust the open side to the requirements. The open sides are automatically processed in the template construction.
A small instruction how to find StecoGuide drill sleeves in 3Shape Implant Studio is available in the Download area.
2.0 mm pilot drill sleeve in 3Shape Implant Studio
/0 Comments/in Allgemein @en, News /by Sascha Metznercontact
steco-system-technik GmbH & Co. KG
head quarter Hamburg
Kollaustraße 6, 22529 Hamburg
Telephone +49 40/55 77 81-0
Fax +49 40/55 77 81 99
email: info@steco.de